Caddy - E.P.A. wood-oil combination furnace
Features
- Model Number: PF01200
- Maximum input capacity : 140.000 BTU (42 kW)
- Furnace exterior dimensions : 26"W x 47"D x 48"H
- Firebox dimensions : 17"W x 22,5"D x 16"H
- Glass door with cast iron frame
- Ash drawer
- Tested by OMNI as per applicable standards (CSA/UL/ULC and/or others)
Options
- Optional fuel oil burner
- Optional insulated vestibule for burner
- Conversion to Riello burner
Click here for more info |
Technical Specs
| Type of fuel |
Wood |
| Maximum input capacity |
140,000 BTU |
| Maximum output capacity |
102,200 BTU |
| Average output capacity |
66,430 BTU |
| Blower |
1/3 HP 4 speed Direct drive, 1300 cfm |
| Loading capacity |
Up to 70 lbs (32 kg) |
| Efficiency |
73 % |
| Color |
Green |
| Exterior dimensions |
26"W x 47"D x 48"H |
| Flue spigot diameter |
6" |
| Recommended exhaust pipe diameter |
7" |
| Type of chimney |
2100°F (1150°C) |
| Recommended chimney diameter |
7" |
| Firebox dimensions |
17"W x 22,5"D x 16"H |
| Maximum log length |
22" |
| Door opening dimensions |
13,75"W x 10"H |
| Type of door |
Glass with cast iron frame |
| Hot air plenum dimensions |
24,5"W x 28,25"D |
| Cold air plenum dimensions |
24,5"W x 15,75"D |
| Ash drawer dimensions |
12"W x 16"D x 3"H |
| Number of filters |
2 |
| Filters dimensions |
12"W x 24"D x 1"H |
| Minimum clearances (Front) |
48" |
| Minimum clearances (Back) |
24" for servicing |
| Minimum clearances (Sides) |
24" for servicing |
| Minimum clearances (Ducts) |
6" for the first six feet and 1" thereafter |
| Recommended clearance (blower maintenance) |
24" |
| Weight |
560 lbs (254 kg) |
| Warranty |
Limited lifetime warranty |
| Test standard - safety |
Can CSA B366.1-M91, CSA B212-93, UL391 3e, Ed. rev. 1999 |
| Test standard - emissions |
E.P.A. |
Oil burner (optional)
| Input capacity |
91,000 BTU (27 kW) |
| Burner orifice |
0,65 gal/h (2,46 l/hr.) |
| Pump pressure |
120 PSI |
| Standard burner |
Beckett AFG |
| Other approuved burners |
Riello, Aero |
| Efficiency |
82 % |
| Burner location |
Right |
| Recommended clearance (Maintenance) |
24" |
| Optional insulated vestibule (Burner) |
Yes |
| Recommended exhaust pipe diameter |
5" |
| Exhaust pipe location |
Left |
|
|
|
|
|
| |